Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38734126

RESUMEN

INTRODUCTION: Physical therapy (PT) is a described first-line treatment option for glenohumeral arthritis, but its efficacy for treating this spectrum of disease is not well understood. The purpose of this study is to evaluate the opinions of expert providers-orthopedic surgeons and physical therapists-regarding the utility of PT in treating glenohumeral arthritis in different stages of radiographic severity. Our goal is to identify areas of interprofessional majority agreement as well as areas without agreement that warrant further investigation. METHODS: A 35-question survey was created and distributed via email to members of the American Shoulder and Elbow Surgeons and the American Society of Shoulder and Elbow Therapists, collecting information on demographics, professional experience, and the perceived benefit of PT for patients with different stages of glenohumeral arthritis based on radiographic severity. Survey responses were analyzed for inter-professional differences in distribution of answer choices as well as for majority agreement statements. Items with > 50% agreement from a professional group were considered statements of majority agreement. RESULTS: 190 surgeons and 39 physical therapists completed the survey. Surgeons and therapists demonstrated different distribution of answer choices in 25 of the 29 non-demographic related questions (86%). Surgeons and therapists reached the same majority statement in eight items (28%) and reached disagreeing majority statements in four items (14%). They agreed on the benefits of PT for mild arthritis, the benefits of corticosteroid injections, the frequency of strengthening exercises, and that PT failure should not be required for surgical approval in patients with severe arthritis. They disagreed on the whether PT exacerbates symptoms in patients with moderate arthritis, and whether preoperative PT influences postoperative outcomes. CONCLUSION: Both surgeons and therapists agreed that PT may be less beneficial for patients with more advanced radiographic arthritis and that PT failure should not be required for insurance approval for surgical intervention in patients with severe glenohumeral arthritis. Further research is needed to determine the efficacy of PT for patients with moderate arthritis as well as the utility of preoperative PT for improving postoperative outcomes.

2.
JSES Rev Rep Tech ; 4(2): 153-160, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38706674

RESUMEN

Background: Humeral fractures (HF) are common orthopedic pathologies. Reviewing the content and quality of influential literature over time is important to advance scientific research regarding a specific topic. This study aims to explore and appraise the fifty most cited HF studies that had been published in orthopedic literature. Methods: The Web of Science database was used to conduct a systematic search for articles pertaining to HF. Articles were sorted out in descending order of citations and were included based on their relevance to HF. Data and metrics of the included studies were recorded. The methodological quality of the studies was assessed using the Modified Coleman Methodology Score (MCMS) and the Methodological Index for Non-randomized Studies criteria. Statistical analysis was conducted to explore any significant relationships between the date of publication and other relevant variables. Results: Included articles (N = 50) were published between 1959 and 2015, with a total of 14,864 accumulated citations. Europe and North America contributed to all but one of the included studies. The Journal of Bone and Joint Surgery contributed to the highest number of included articles with 27 articles (54%). The proximal humerus was the most commonly explored HF location in our study (72%). The average MCMS and Methodological Index for Non-randomized Studies scores were reported to be 64.6 and 10.4, respectively, and the majority of articles (52%) were considered level four case series. Year of publication was found to have a positive correlation with increasing level of evidence(r = -0.301, P = .044), citation density (r = 0.734, P < .001), and MCMS score (r = 0.41, P = .01). Conclusion: The level of evidence, MCMS scores, and citation density of influential HF literature has been increasing with time, reflecting the increasing effort and work being put in that field. While the findings seem encouraging, additional high-quality research is needed to help achieve better treatment strategies and outcomes.

3.
J Orthop Case Rep ; 14(3): 146-151, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38560328

RESUMEN

Introduction: The subacromial balloon is a novel therapeutic device that is used in patients with massive irreparable rotator cuff tears (MIRCTs). The novelty of this device implies that there is still a lot to be known about its mechanism of action and rehabilitation trends. One rehabilitation trend that has been noticed is the "balloon dip", where a patient exhibits exacerbations in pain and function around 3 months following balloon implantation and after having experienced earlier symptomatic relief post-operative. We discuss the clinical, diagnostic, and therapeutic aspects of the patient's management while providing additional insight into this prognostic trend. Case Report: In this report, we present the case of a 65-year-old male patient who underwent a subacromial balloon procedure for a MIRCT. During his recovery, the patient exhibited a classic "balloon dip" evident by an exacerbation of pain and function around the 3-month mark. After a notable deterioration in pain and function, the patient was examined, reassured, and educated on the importance of adhering to physical therapy. He was able to successfully recover and showed gradual improvement in pain and function along the course of the year. Conclusion: The "balloon dip" is a rehabilitation pattern that occurs 3-6 months following subacromial balloon spacer implantation. In the majority of cases, careful clinical assessment, watchful monitoring, and education on the importance of following up with physical therapy are sufficient to overcome the dip.

4.
Arthrosc Sports Med Rehabil ; 6(2): 100907, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38495636

RESUMEN

Purpose: To examine long-term patient-reported outcomes and range of motion in patients with massive irreparable rotator cuff tears (MIRCTs) who underwent subacromial balloon spacer implantation. Methods: A retrospective review of all patients who underwent subacromial balloon placement procedure for MIRCTs at our institution was conducted. Patients with adequate preoperative and postoperative data, with at least 5 years of follow-up, were included in our study. Outcome measures were range of motion (forward elevation), American Shoulder and Elbow Surgeon (ASES) score, and visual analog scale (VAS) score. Independent t test was conducted to check for statistically significant differences between preoperative and postoperative outcome scores, with P < .05 deemed significant. Results: Ten patients were identified: 4 were lost to follow-up beyond 2 years and were excluded. One was converted to an arthroplasty at the 1-year mark and was then lost to follow-up (conversion rate: 16.6%). Five patients had at least 5 years of follow-up after the balloon procedure and were involved in our case series analysis. Mean age was 63.1 years, and mean follow-up was 5.8 years (range, 5-7 years). Preoperatively, mean forward elevation was 110 degrees, mean ASES score was 40.68, and mean VAS score was 6.2. On follow-up, mean forward elevation was 163 degrees (P = .007), mean ASES score was 90.97 (P = .001), and mean VAS score was 0.9 (P = .004). All patients showed significant improvements in all outcome measures, and none had any significant complications. Conclusions: In this study, we found that the use of a subacromial balloon spacer can lead to good outcomes at a minimum 5-year follow-up in patients with MIRCTs. Level of Evidence: Level IV, therapeutic case series.

5.
Opt Express ; 32(4): 6011-6024, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38439314

RESUMEN

Monitoring the temperature distribution within a local environment at the micro and nanoscale is vital as many processes are solely thermal. Various thermometric techniques have been explored in the community, and out of these, fluorescent nano/micro particle-based mechanisms are accepted widely (fluorescence intensity ratio (FIR) techniques, where the ratio of populations in two consecutive energy levels is compared with Boltzmann distribution). We describe a new technique to account for the temperature rise near an illuminated upconverting particle (UCP) using wavefront imaging, which is more sensitive than the conventional thermometric techniques on the microscale. We rely on a thermo-optical phase microscopic technique by reconstructing the wavefront of emission from an upconverting particle using a Shack-Hartmann wavefront sensor. The wavefront maps the local phase distribution, which is an indicator of the surroundings' optical parameters, particularly the suspended medium's temperature-induced refractive index in the presence of convection currents. We describe how these extracted phase values can provide information about the optical heating due to the particle and hence its local environment along the direction of the emission. Our findings demonstrate the detection of a minimum temperature rise of 0.23 K, while the FIR methods indicate a minimum of 0.3 K rise. This technique is used to study the temperature increase in the backscattered direction for an upconverting particle illuminated on pump resonance. We also estimate the Soret coefficient for an upconverting particle optically trapped on pump resonance and experiencing anisotropic heating across the body.

6.
ACS Appl Mater Interfaces ; 16(8): 10969-10983, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38355426

RESUMEN

The interaction of graphene with metals initiates charge-transfer interaction-induced chemical enhancements, which critically depend on the doping effect from deposited metallic configurations. In this paper, we have explored the gold nanoparticle-decorated monolayer graphene nanosheets for the large graphene-induced Raman enhancement of adsorbed analytes, indicating the surface-enhanced Raman spectroscopy (SERS) capabilities of metal-doped graphene (G-SERS). Here, the systematically sputtered Au thickness optimization procedure revealed noticeable modifications in the graphene Raman spectra and photoluminescence (PL) background quenching, which indicated favorable charge transfer through n-type doping of chemical vapor deposition-grown graphene nanosheets. The highly consistent, individually distributed morphology of the gold nanoislands over graphene nanosheets depicted a reproducibly uniform G-SERS signal with excellent relative standard deviation values (<5%), resulting in the strongest Raman intensity enhancement factors of ∼108 (MB) (methylene blue) and 107 (DPA) (2,6-pyridinedicarboxylic acid) composed of the weakest PL background. The combined charge-transfer-induced chemical enhancement and electromagnetic enhancement from individual Au nanoislands result in a lowering of detectability down to 10-16 M (MB) and 10-11 M (DPA) concentrations with efficient time-dependent signal stability. Additionally, the GAu demonstrated its effective (∼94.4%) photocatalytic degradation capabilities by decomposing MB dye molecules from a concentration of 1 µM to 2.52 fM within 60 min. Therefore, the prominent charge-transfer contribution through controlled Au decoration over graphene nanosheets provides a potential strategy for fabricating superior SERS sensors and photocatalysts exhibiting adequate signal consistency, stability, and photodegradation efficiency through overcoming the limitations of the traditional sensing platforms.

7.
J Minim Access Surg ; 20(1): 89-95, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38240384

RESUMEN

INTRODUCTION: The most dreaded complication during laparoscopic cholecystectomy still remains to be injury to the common bile duct. The primary cause for bile duct injury during LC is misinterpretation of the biliary anatomy. Intra-operative cholangiography was introduced as a means of reducing the chances of biliary injury, done using Fluoroscopic imaging or Near-infrared fluorescence imaging method. NIRF is one of the most popular imaging methods in biomedical sciences. Indocyanine Green is sterile and water soluble which completely binds to albumin and is excreted in bile. PATIENTS AND METHODS: This prospective study was conducted among 70 patients between July 2020 and December 2021. Subjects were administered 5mg of ICG dye pre-operatively and procedure performed using Karl Storz HD image S1 system with a D-light P light source for NIRF imaging. RESULTS: The average duration of surgery was 58.10 minutes. After calot's dissection, the CBD was visualized in 88.71 % patients, with a mean time to visualization at 26.33 minutes. The cystic duct was visualized in 87.3% cases with a mean time of visualization of 32.10 minutes. The hepatic duct was visualized in 28.57% and the hepatic duct-CBD confluence was visualized in 34.28% patients. CONCLUSION: Near infrared imaging based intra-operative cholangiography, using Indocyanine Green dye, during Lap. Cholecystectomy is an easy, useful and inexpensive method of visualizing the biliary ductal anatomy.

8.
R I Med J (2013) ; 107(2): 40-43, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38285752

RESUMEN

BACKGROUND: This study aims to provide insight regarding the different qualities of international medical graduates (IMGs) involved in US orthopedic residency programs. METHODS: Orthopedic residency programs accredited by the ACGME and listed in the AMA database were screened. Data on program size and location, IMG year of training, the geographic region of IMG's medical schools, their research experiences and number of gap years were included. RESULTS: A total of 167(80.3%) orthopedic residency programs were included. A total of 3838 residents were identified, of which 44 (1.15%) were IMGs. The United Kingdom and Ireland had the highest number of matched IMGs with four (9.1%) each. Massachusetts was the state with the highest number of enrolled IMGs. On average, IMGs had 26.3 publications and joined US orthopedic residency 4.66 years following medical school graduation. CONCLUSION: Despite the many hurdles experienced by IMGs, a decent number succeeds in matching into US orthopedic residency programs each year.


Asunto(s)
Internado y Residencia , Humanos , Estados Unidos , Médicos Graduados Extranjeros , Educación de Postgrado en Medicina , Evaluación Educacional , Facultades de Medicina
9.
Clin Shoulder Elb ; 27(1): 117-125, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37442777

RESUMEN

While shoulder hemiarthroplasty is still used to treat young patients with shoulder pathology, the use of this procedure has substantially declined in recent years due to its significant complication profile. Glenoid wear with arthrosis is one of the major postoperative complications following shoulder hemiarthroplasty, and efforts to prevent this complication led many scientists to explore alternative weight-bearing surfaces on arthroplasty implants to decrease joint wear and improve patient outcomes. Pyrolytic carbon, or pyrocarbon, is a material that has better biocompatibility, survivorship, strength, and wear resistance compared to the materials used in traditional shoulder hemiarthroplasty. Pyrocarbon implants have been used in orthopedics for over 50 years; recently, their utility in shoulder hemiarthroplasty has garnered much interest. The purpose behind the use of pyrocarbon in shoulder hemiarthroplasty is to decrease the risk of progressive glenoid wear, especially in young active patients in whom joint preservation is important. Promising survivorship and outcomes have been demonstrated by recent studies, including limited glenoid wear following pyrocarbon hemiarthroplasty. Nevertheless, these clinical studies have been limited to relatively small case series with limited long-term follow-up. Accordingly, additional research and comparative studies need to be conducted in order to properly assess the therapeutic efficacy and value of pyrocarbon hemiarthroplasty.

10.
Clin Shoulder Elb ; 27(1): 26-31, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38147873

RESUMEN

BACKGROUND: The coracoacromial ligament (CAL) is frequently observed to be damaged during arthroscopy and it is unclear how demographic, anatomic, and radiographic factors are related to CAL degeneration in full-thickness rotator cuff tears. METHODS: A prospective study was conducted of patients at a single institution undergoing shoulder arthroscopy for first-time, full-thickness rotator cuff tears. We evaluated preoperative anteroposterior radiographs to obtain critical shoulder angle, glenoid inclination, acromial index, acromiohumeral distance, lateral acromial angle, and acromial morphology. We documented CAL quality, rotator cuff tear size and pattern during arthroscopy. Multiple logistic regression was used to identify predictive factors for encountering severe CAL fraying during arthroscopy. RESULTS: Shoulders had mild CAL degeneration in 58.1% of cases, whereas severe CAL degeneration was present in 41.9% of shoulders. Patients with severe CAL attrition were significantly older (62.0 years vs. 58.0 years, P=0.042). Shoulders with severe CAL attrition had large rotator cuff tears in 54.1% of cases (P<0.001), and tears involving the infraspinatus (63.2% vs. 29.6%, P=0.003). The severe degeneration group was more likely to have a larger critical shoulder angle measurement on preoperative radiographs than those in the mild attrition group (36.1°±3.6° [range, 30°-45°] vs. 34.1°±3.8° [range, 26°-45°], P=0.037). CONCLUSIONS: While the clinical impact of CAL degeneration remains uncertain, increased severity of CAL degeneration is associated with older age, larger rotator cuff tear size, presence of infraspinatus tearing, and increased preoperative critical shoulder angle. Level of evidence: III.

11.
Clin Shoulder Elb ; 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-38062720

RESUMEN

Several surgical procedures have been proposed to address anterior glenohumeral instability, which is one of the most common complaints in the general population. The remplissage, first described in early 2000s, is a procedure performed simultaneously with the arthroscopic Bankart repair to correct large, engaging Hill-Sachs lesions (HSLs). This procedure stabilizes the joint by tenodesing the infraspinatus tendon into the HSL to fill and disengage the defect. This procedure gained popularity because it has relatively low risk and is able to improve shoulder stability while being less invasive than other bone-blocking procedures. The remplissage has become a valuable add-on technique that can substantially improve outcomes in unstable patients undergoing arthroscopic Bankart repair. Nevertheless, several studies in the literature have raised concerns regarding its efficacy in critically unstable patients and the potential range of motion limitations that can arise postoperatively. Additional comparative studies and trials should be conducted to appropriately establish the role of remplissage in treating anterior instability, especially in patients with critical bone loss.

12.
Clin Shoulder Elb ; 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38147874

RESUMEN

As the population is aging and indications are expanding, shoulder arthroplasty is becoming more frequent, especially bilateral staged replacement. However, surgeons are hesitant to use bilateral reverse prostheses due to potential limitations on activities of daily living. This meta-analysis was conducted to compare bilateral anatomic to bilateral reverse shoulder implants. PubMed, Cochrane, and Google Scholar (pages 1-20) were searched until April 2023. The clinical outcomes consisted of postoperative functional scores (American Shoulder and Elbow Surgeons [ASES], Single Assessment Numeric Evaluation [SANE], Physical Component Score [PCS], Mental Component Score, and Simple Shoulder Test), pain, and range of motion (external rotation and forward elevation). Three studies were included in this meta-analysis. Bilateral anatomic implants had better postoperative functional outcomes and range of motion, but no significant difference was seen in postoperative pain when compared to the reverse prosthesis. Better ASES score, SANE score, and PCS as well as better external rotation and forward elevation were seen in the bilateral anatomic shoulder replacement group, but no significant difference in pain levels was seen between the two groups. These results may be explained by the lower baseline seen in the reverse prosthesis group, which may be due to an older population and different indications. Nevertheless, more randomized controlled studies are needed to confirm these findings.

13.
JSES Int ; 7(6): 2534-2541, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37969495

RESUMEN

Background: ChatGPT is an artificial intelligence (AI) language processing model that uses deep learning to generate human-like responses to natural language inputs. Its potential use in health care has raised questions and several studies have assessed its effectiveness in writing articles, clinical reasoning, and solving complex questions. This study aims to investigate ChatGPT's capabilities and implications in diagnosing and managing patients with new shoulder and elbow complaints in a private clinical setting to provide insights into its potential use as a diagnostic tool for patients and a first consultation resource for primary physicians. Methods: In a private clinical setting, patients were assessed by ChatGPT after being seen by a shoulder and elbow specialist for shoulder and elbow symptoms. To be assessed by the AI model, a research fellow filled out a standardized form (including age, gender, major comorbidities, symptoms and the localization, natural history, and duration, any associated symptoms or movement deficit, aggravating/relieving factors, and x-ray/imaging report if present). This form was submitted through the ChatGPT portal and the AI model was asked for a diagnosis and best management modality. Results: A total of 29 patients with 15 males and 14 females, were included in this study. The AI model was able to correctly choose the diagnosis and management in 93% (27/29) and 83% (24/29) of the patients, respectively. Furthermore, of the remaining 24 patients that were managed correctly, ChatGPT did not specify the appropriate management in 6 patients and chose only one management in 5 patients, where both were applicable and dependent on the patient's choice. Therefore, 55% of ChatGPT's management was poor. Conclusion: ChatGPT made a worthy opponent; however, it will not be able to replace in its current form a shoulder and elbow specialist in diagnosing and treating patients for many reasons such as misdiagnosis, poor management, lack of empathy and interactions with patients, its dependence on magnetic resonance imaging reports, and its lack of new knowledge.

14.
Epilepsy Behav ; 148: 109465, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37844441

RESUMEN

PURPOSE: Benign Epilepsy with Centro-Temporal Spikes (BECTS) is a pediatric epilepsy with typically good seizure control. Although BECTS may increase patients' risk of developing neurological comorbidities, their clinical care and short-term outcomes are poorly quantified. METHODS: We retrospectively assessed adherence to National Institute for Health and Care Excellence (NICE) guidelines relating to specialist referral, electroencephalogram (EEG) conduct and annual review in the care of patients with BECTS, and measured their seizure, neurodevelopmental and learning outcomes at three years post-diagnosis. RESULTS: Across ten centers in England, we identified 124 patients (74 male) diagnosed with BECTS between 2015 and 2017. Patients had a mean age at diagnosis of 8.0 (95% CI = 7.6-8.4) years. 24/95 (25%) patients were seen by a specialist within two weeks of presentation; 59/100 (59%) received an EEG within two weeks of request; and 59/114 (52%) were reviewed annually. At three years post-diagnosis, 32/114 (28%) experienced ongoing seizures; 26/114 (23%) had reported poor school progress; 15/114 (13%) were diagnosed with a neurodevelopmental disorder (six autism spectrum disorder, six attention-deficit/hyperactivity disorder); and 10/114 (8.8%) were diagnosed with a learning difficulty (three processing deficit, three dyslexia). Center-level random effects models estimated neurodevelopmental diagnoses in 9% (95% CI: 2-16%) of patients and learning difficulty diagnoses in 7% (95% CI: 2-12%). CONCLUSIONS: In this multicenter work, we found variable adherence to NICE guidelines in the care of patients with BECTS and identified a notable level of neurological comorbidity. Patients with BECTS may benefit from enhanced cognitive and behavioral assessment and monitoring.


Asunto(s)
Trastorno del Espectro Autista , Epilepsia Rolándica , Humanos , Niño , Masculino , Epilepsia Rolándica/diagnóstico , Epilepsia Rolándica/epidemiología , Epilepsia Rolándica/psicología , Estudios Retrospectivos , Trastorno del Espectro Autista/complicaciones , Trastorno del Espectro Autista/diagnóstico , Trastorno del Espectro Autista/epidemiología , Convulsiones , Electroencefalografía
15.
Data Brief ; 50: 109463, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37588616

RESUMEN

This article presents a comprehensive dataset extracted from published annual, sustainability and integrated reports, focusing on environmental (GRI300) and social (GRI400) disclosures, for the top 100 Malaysian public listed companies (based on Market Capitalization as of 31 December 2016). The dataset covers three years (2018 to 2020) with 300 firm-year observations. Environmental and Social disclosure scores were calculated using the Global Reporting Initiative (GRI) framework and derived from the content analysis of the companies' reports accessed from respective corporate or Bursa Malaysia's websites. A binary scoring method (one for disclosure or zero, otherwise for each environmental and social disclosure item) was employed. This scoring process underwent three stages of rigorous manual verification protocol: initial check and scoring by research assistants, review by the research team, and a final review by an independent external accounting firm for validation. This dataset is valuable for academics, practitioners, and policymakers to evaluate corporate alignment with UN Sustainable Development Goal (SDG) #12, encouraging Responsible Consumption and Production, and shape strategic policies to meet Bursa compliance for enhanced corporate sustainability. It further aids in investigating associations between governance factors and other firm characteristics with environmental and social disclosures.

16.
Phys Chem Chem Phys ; 25(32): 21736-21747, 2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37552204

RESUMEN

A large power factor and ultralow lattice thermal conductivity in 2D-monolayers of AuX (X = Cu and Ag) are achieved via first principles calculations. Low phonon frequency, small Debye temperature and high Gruneisen parameter limit the intrinsic thermal conductivity of both the studied materials. An ultra-low lattice thermal conductivity of 0.13 (0.30) W m-1 K-1 and 0.66 (1.59) W m-1 K-1 is obtained for unstrained AuCu and AuAg monolayers, respectively, at 700 (300) K, which further reduces to 0.04 (0.09) and 0.26 (0.63) W m-1 K-1 at 6% biaxial tensile strain. Such values of thermal conductivity are lower than the critical thermal conductivity for the state-of-art thermoelectric materials (kl < 2 W m-1 K-1). The peak values of ZT for unstrained monolayers are 2.20 and 1.40, which enhances to 3.61 and 2.91 at 6% strain for AuCu and AuAg monolayers, respectively. Interestingly pudding-mold band textures are found to be responsible for this unusual thermoelectric behaviour. The stability concerns (chemical/dynamic/mechanical) of these monolayers are ensured to stimulate experimental determinations for novel synthesis and possible applications.

17.
Chemosphere ; 339: 139735, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37544527

RESUMEN

We report the preparation of Ag nanoparticles functionalized MoS2 nanoflakes by using the chemical reduction method followed by the hydrothermal method. Field emission scanning electron microscopy and elemental mapping reveals the uniform functionalization of Ag nanoparticles with MoS2 nanoflakes. High density of Ag plasmonic nanoparticles onto MoS2 nanoflakes demonstrates tremendously improved charge separation behavior in Ag-MoS2 nanohybrids. Photodecomposition capability of plasmonic Ag-MoS2 nanohybrids was explored by the decomposition of industrial pollutant molecules, showing a direct correlation between the Ag content over the MoS2 surface with their photodecomposition ability. The SERS-based detection profiles of the plasmonic were investigated by the ultra-low detection of MB molecules. The Ag-MoS2 nanohybrids SERS substrate manifests the detection of MB molecules solution up to a concentration of 10-9 M with an enhancement factor of 107. In the current study, we proposed and elucidated the probable efficient charge transfer mechanism for improved photocatalytic behavior and SERS-based sensing performance.


Asunto(s)
Contaminantes Ambientales , Nanopartículas del Metal , Nanopartículas del Metal/química , Molibdeno/química , Espectrometría Raman/métodos , Plata/química
18.
Nat Chem Biol ; 19(12): 1513-1523, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37653169

RESUMEN

The cullin-RING ubiquitin ligase (CRL) network comprises over 300 unique complexes that switch from inactive to activated conformations upon site-specific cullin modification by the ubiquitin-like protein NEDD8. Assessing cellular repertoires of activated CRL complexes is critical for understanding eukaryotic regulation. However, probes surveying networks controlled by site-specific ubiquitin-like protein modifications are lacking. We developed a synthetic antibody recognizing the active conformation of NEDD8-linked cullins. Implementing the probe to profile cellular networks of activated CUL1-, CUL2-, CUL3- and CUL4-containing E3s revealed the complexes responding to stimuli. Profiling several cell types showed their baseline neddylated CRL repertoires vary, and prime efficiency of targeted protein degradation. Our probe also unveiled differential rewiring of CRL networks across distinct primary cell activation pathways. Thus, conformation-specific probes can permit nonenzymatic activity-based profiling across a system of numerous multiprotein complexes, which in the case of neddylated CRLs reveals widespread regulation and could facilitate the development of degrader drugs.


Asunto(s)
Proteínas Cullin , Ubiquitina-Proteína Ligasas , Proteínas Cullin/genética , Ubiquitinación , Ubiquitina-Proteína Ligasas/metabolismo , Ubiquitina/metabolismo , Ubiquitinas/metabolismo , Proteína NEDD8/metabolismo
19.
Clin Shoulder Elb ; 26(3): 238-244, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37607858

RESUMEN

BACKGROUND: Many patients use online resources to educate themselves on surgical procedures and make well-informed healthcare decisions. The aim of our study was to evaluate the quality and readability of online resources exploring shoulder arthroplasty. METHODS: An internet search pertaining to shoulder arthroplasty (partial, anatomic, and reverse) was conducted using the three most popular online search engines. The top 25 results generated from each term in each search engine were included. Webpages were excluded if they were duplicates, advertised by search engines, subpages of other pages, required payments or subscription, or were irrelevant to our scope. Webpages were classified into different source categories. Quality of information was assessed by HONcode certification, Journal of the American Medical Association (JAMA) criteria, and DISCERN benchmark criteria. Webpage readability was assessed using the Flesch reading ease score (FRES). RESULTS: Our final dataset included 125 web pages. Academic sources were the most common with 45 web pages (36.0%) followed by physician/private practice with 39 web pages (31.2%). The mean JAMA and DISCERN scores for all web pages were 1.96±1.31 and 51.4±10.7, respectively. The total mean FRES score was 44.0±11.0. Only nine web pages (7.2%) were HONcode certified. Websites specified for healthcare professionals had the highest JAMA and DISCERN scores with means of 2.92±0.90 and 57.96±8.91, respectively (P<0.001). HONcode-certified webpages had higher quality and readability scores than other web pages. CONCLUSIONS: Web-based patient resources for shoulder arthroplasty information did not show high-quality scores and easy readability. When presenting medical information, sources should maintain a balance between readability and quality and should seek HONcode certification as it helps establish the reliability and accessibility of the presented information. Level of evidence: IV.

20.
J Clin Sleep Med ; 19(10): 1823-1833, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37394867

RESUMEN

Since the publication of its 2020 position statement on artificial intelligence (AI) in sleep medicine by the American Academy of Sleep Medicine, there has been a tremendous expansion of AI-related software and hardware options for sleep clinicians. To help clinicians understand the current state of AI and sleep medicine, and to further enable these solutions to be adopted into clinical practice, a discussion panel was conducted on June 7, 2022, at the Associated Professional Sleep Societies Sleep Conference in Charlotte, North Carolina. The article is a summary of key discussion points from this session, including aspects of considerations for the clinician in evaluating AI-enabled solutions including but not limited to what steps might be taken both by the Food and Drug Administration and clinicians to protect patients, logistical issues, technical challenges, billing and compliance considerations, education and training considerations, and other unique challenges specific to AI-enabled solutions. Our summary of this session is meant to support clinicians in efforts to assist in the clinical care of patients with sleep disorders utilizing AI-enabled solutions. CITATION: Bandyopadhyay A, Bae C, Cheng H, et al. Smart sleep: what to consider when adopting AI-enabled solutions in clinical practice of sleep medicine. J Clin Sleep Med. 2023;19(10):1823-1833.


Asunto(s)
Inteligencia Artificial , Médicos , Humanos , Estados Unidos , Programas Informáticos , Sociedades Médicas , Sueño
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...